Items | Specifications |
Input Voltage | 220V/380V/415V/460V 3 PHASE 5060HZ |
Output Frequency | 0HZ~3000HZ |
Frequency resolution | 0.01HZ |
Overload Capability | 150% rated current for 1 minute, 180% rated current for 3 seconds |
Torque control accuracy | ±5%(FVC) |
Control mode | Scalar Control(V/F),sensorless vector control(SVC), Speed SensorVector Control(Fvc) |
Start Frequency | 0.4HZ~20HZ |
Torgue boost | Auto torque boost, manual torque boost 0.1%~30.0% |
V/F curve | Five ways: constant torque V/F curve, 1 kind of user defined V/F curve ,3kinds of down torque curve(2.0/1.7/1.2times the power) |
Acc./Dec. curve | Two ways: linear Acc./Dec.,S-curveAcc./Dec.;7 kinds of Acc./Dec. timeTime unit(minute/second)optional, max.time. 6000 minutes |
DC braking | DC Braking Frequency:000Hz~ Max Frequency Braking Time.0.0s~36.0s Braking Action Current Value:0.0%~100.0% |
Energy consuming braking | Below 22Kw drive built-in energy consuming braking unit, externalbraking resistor is optional. |
Build-in Double PlD | Easily constitute a close loop control system |
Short time continuous working when power failure | when the instantaneous power failure occurs, the load side regenerative energy compensate the voltage drop and the inverter keeprunning for a short time. |
Multi-stage speed running | Max 16 multi-stage speed running via build-in PLc or control terminals |
Textile swing frequency | Swing frequency available with preset and central frequency adjustable |
Auto voltage regulation | Keep a stable voltage automatically when the grid voltage transients |
Auto current limiting | Auto current limiting to prevent frequent over current fault trip |
Multi pumps control | With water supply kit, it can implement multi pumps constant pressurewater supply |
Communication Protocal | MODBUS RS485 |
Running command channel | Keypad , Control terminal , Serial port , Above 3 channels are switchable |
Switch input channel | FWD/REV command: 8channels programmable switch inputs, 52kinds offunction can be set separately |
Analog input channel | 4~20mA: 0-10V:2 optional analog inputs |
Analog output channel | 4~20mA or 0~10V optional, setting frequency and output frequency ,etcfeature output |
Switch/pulse output channel | Programmable open collector output: relay output :0~20KHz pulseoutput. |
Parameter copy | Yuanxin PC software for parameter setting & commission |
Protection function | Overcurrentprotection:overvoltageprotection.undervoltageprotection.overheating protection: overload protection,etc.Input phaseloss protection (model>2.2kw) |
Altitude | Lower than 1000m (derating is necessary above 1000m) |
Environment | Indoors, avoid from direct sunlight, dust, corrosive gas, oil mist, steamwater dropper salt, etc |