Customization: | Available |
---|---|
Application: | Three Phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 55/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Voltage level | Models | Rated capacity(K/A) |
Rated output |
Applicable motor(KW) |
220V Single phase | YX9000-2S0004G | 1.1 | 3.0 | 0.4 |
YX9000-2S0007G | 1.5 | 4.7 | 0.75 | |
YX9000-2S0015G | 2.8 | 7.5 | 1.5 | |
YX9000-2S0022G | 3.8 | 10.0 | 2.2 | |
220V Three phase | YX9000-2T0015G | 3.0 | 7.0 | 1.5 |
YX9000-2T0022G | 4.0 | 10.0 | 2.2 | |
380V Three phase |
YX9000-4T0007G | 1.5 | 2.5 | 0.75 |
YX9000-4T0015G | 2.5 | 4.0 | 1.5 | |
YX9000-4T0022G | 3.0 | 6.0 | 2.2 | |
YX9000-4T0037G | 5.9 | 9.6 | 3.7 | |
YX9000-4T0055G | 8.5 | 14.0 | 5.5 | |
YX9000-4T0075G | 11 | 17.0 | 7.5 | |
YX9000-4T0110G | 17 | 25 | 11 | |
YX9000-4T0150G | 21.7 | 32 | 15 | |
YX9000-4T0185G | 25.7 | 39 | 18.5 | |
YX9000-4T0220G | 29.6 | 45 | 22 | |
YX9000-4T0300G | 39.5 | 60 | 30 | |
YX9000-4T0370G | 49.4 | 75 | 37 | |
YX9000-4T0450G | 60 | 91 | 45 | |
YX9000-4T0550G | 73.7 | 112 | 55 | |
YX9000-4T0750G | 99 | 150 | 75 | |
YX9000-4T0900G | 116 | 176 | 90 | |
YX9000-4T1100G | 138 | 210 | 110 | |
YX9000-4T1320G | 167 | 253 | 132 | |
YX9000-4T1600G | 200 | 304 | 160 | |
YX9000-4T1850G | 234 | 355 | 187 | |
YX9000-4T2000G | 248 | 377 | 200 | |
YX9000-4T2200G | 280 | 426 | 220 | |
YX9000-4T2500G | 318 | 474 | 250 | |
YX9000-4T2800G | 342 | 520 | 280 | |
YX9000-4T3150G | 390 | 600 | 315 | |
380V Three phase |
YX9000-4T3500G | 435 | 660 | 350 |
YX9000-4T4000G | 493 | 750 | 400 | |
YX9000-4T4500G | 560 | 850 | 450 |
Items | Specifications | |
Input | Rated Voltage | three phase 380V;50Hz/60Hz |
Range | Voltage: ±20% voltage unbalance rate:<3%; frequency: ±5% | |
Output | Rated voltage | 380V |
Frequency range | 0Hz~500Hz | |
Frequency resolution | 0.01Hz | |
Overload ability | 150% rated current for1minute, 180% rated current for3 seconds | |
Control function Control function |
Modulation modes | Optimized space voltage vector SVPWM modulation |
Control mode | V/F, Sensor less vector and Closed loop vector control | |
Frequency accuracy | Digital setting: The highest frequency×± 0.01% Analog setting: The highest frequency ×±0.2% | |
Frequency resolution | Digital setting: 0.01Hz; Analog setting: The highest frequency× 0.1% | |
Start frequency | 0.40Hz~20.00Hz | |
Torque boost | Auto torque boost, manual torque boost 0.1%~30.0% | |
V/F curve | Five ways: constant torque V/F curve, 1 kind of user defined V/F curve ,3 kinds of down torque curve(2.0/1.7/1.2times the power) |
|
Acc./Dec. curve | Two ways: linear Acc./Dec.,S-curveAcc./Dec.;7 kinds of Acc./Dec. time, Time unite (minute/second) optional, max time: 6000 minutes. |
|
DC braking | DC braking start frequency:0~15.00Hz braking time:0~60.0s braking current:0~80% |
|
Energy consuming braking | Below 22KW drive built-in energy consuming braking unit, 30-37KW built-in braking unit optional, external braking resistor is optional. | |
Jog running | Jog frequency range:0.1Hz~50.00Hz, JOG Acc./Dec. time: 0.1~60.0s | |
PI built-in | Easily constitute a close loop control system | |
Multi-stage speed running | Multi-stage speed running available through built-in PLC or control terminals | |
Textile swing frequency | Swing frequency available with preset and central frequency adjustable | |
Auto voltage regulation | Keep a stable voltage automatically when the grid voltage transients | |
Auto energy saving running | Saving energy by auto optimizing V/F curve according to the load | |
Auto current limiting | Auto current limiting to prevent frequent over current fault trip | |
Multi pumps control | With water supply card, the function can implement multi pumps constant pressure water supply | |
Communication | 4 field bus: Modbus, Profibus, CANlink, CANopen | |
Running function |
Running command channel | Control panel : control terminal :serial port :3 channels switchable |
Frequency setting channel | Control panel potentiometer setting: up/down control panel keys setting; Function code setting: Serial port setting; Terminal up/down setting: Input Analog voltage setting: Input Analog current setting: Input pulse setting; Combination ways setting; Above ways are switchable. |
|
Switch input channel | FWD/REV command: 8channels programmable switch inputs, 35kinds of function can be set separately | |
Analog input channel | 4~20mA: 0-10V: 2 optional analog inputs | |
Analog output channel | 4~20mA or 0~10V optional, setting frequency and output frequency ,etc feature output |
|
Switch/pulse output channel | 2 channels Programmable open collectors output, 2 channels relays output, 1 channel 0~20KHz pulse output | |
Control panel | LED digital display | Display setting frequency, output voltage, output current, etc. |
External meter display | Display output frequency, output current, output voltage, etc. | |
Key lock | All the keys can be locked | |
Parameter copy | Function code parameters are able to be copied between inverters when use remote control panel. | |
Protection function | Overcurrent protection; overvoltage protection; undervoltage protection; overheating protection; overload protection, etc. | |
Optional parts | Braking unit: remote control panel: cable: panel mounting feet, etc. | |
Environment | Environment | Indoors, free from direct sunlight, dust, corrosive gas, oil mist, steam, water dropper salt, etc |
Altitude | Lower than 1000m (derating is necessary above 1000m) | |
Ambient temperature | -10ºC~+40ºC | |
Humidity | <90%RH, no condensation | |
Vibration | Lower than 5.9m/s (0.6g) | |
Storage temperature | -20ºC~+60ºC | |
Structure | Protection level | IP20(In the selection of state display unit or the keyboard state) |
Cooling | Forced air cooling | |
Installation | Wall mounted; Floor mounted |
Suitable for OEM Machine builder
Widely applied in textiles, packaging, printing, pharmacy industry ,etc .