Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
5.5 kW Single Phase to Three phase Frequency Inverter
FK series frequency drive inverter for sale, convert single phase to three phase for AC motor speed controls, speed regulation 1:100. With IP20 protection, variable frequency drive single phase to 3 phase has RS485 communication mode, and PID controller is convenient to make closed-loop system. The single phase to 3 phase inverter is usually applied in motor, pump, electric equipment and so on.
Basics | Model | YX9000 series |
Power capacity | 5.5KW/7.5HP | |
Color | Black in standard, other colors in optional | |
Control mode | Vector control | |
I/O Features | Input voltage | 1 phase 220V(range:176V-264V); 3 phase 380V(range:304V-456V); 3 phase 415V(range:323V-528V); 3 phase 220V(range:176V-264V) |
Output voltage | 0-input voltage | |
Input frequency | 50/60Hz | |
Output frequency | 0-500Hz | |
Rated output current | 14A | |
Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
Control Feature | Communication | RS485 |
Speed regulation | 1:100 | |
Start torque | 150% of rating torque at 1 Hz | |
Speed control accuracy | ≤±0.5% of rating synchronous speed | |
Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% |
|
Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz |
|
Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
Interior PID controller | Be convenient to make closed-loop system | |
Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
Environment | Enclosure rating | |
Temperature | -10ºC~ +40ºC; VFD will be derated if ambient temperature exceed 40ºC; each rise 1ºC, the derate will be 5% | |
Humidity | 5%-95%, without condensation | |
Altitude | ≤1000m; VFD will be derated if above 1000m | |
Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
Store environment |
|
1. Use the diode position of the multimeter, the red pen to point the three-phase output terminals (U, V, W), the black pen point "+", measure whether the three-phase bridge on the inverter part is normal or not, and the multimeter shown about 0.4V is Normal, short circuit or open circuit means damage, as shown in left picture.