Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items | Specifications |
Rated Input Voltage | 220V / 380V / 415V / 440V; 50Hz/60Hz |
Tolerance | Voltage: ±20% voltage unbalance rate:<3%; frequency: ±5% |
Rated Output voltage | 220V /380V / 415V / 440V |
Frequency range | 0Hz~5000Hz |
Frequency resolution | 0.01Hz |
Overload capability | 150% rated current for 1 minute, 180% rated current for 3 seconds |
Torque control accuracy | ±5%(FVC) |
Control mode | V/F, sensorless vector control (SVC), Speed Sensor vector control(FVC) |
Frequency Accuracy | Digital setting: The highest frequency×± 0.01% Analog setting: The highest frequency ×±0.2% |
Frequency resolution | Digital setting: 0.01Hz; Analog setting: The highest frequency× 0.1% |
Start frequency | 0.40Hz~20.00Hz |
Torque boost | Auto torque boost, manual torque boost 0.1%~30.0% |
V/F curve | Five ways: constant torque V/F curve, 1 kind of user defined V/F curve ,3 kinds of down torque curve(2.0/1.7/1.2times the power) |
Acc./Dec. curve | Two ways: linear Acc./Dec.,S-curveAcc./Dec.;7 kinds of Acc./Dec. time, Time unit(minute/second) optional, max. time: 6000 minutes. |
DC braking | DC Braking Frequency: 000Hz~ Max Frequency Braking Time: 0.0s~36.0s Braking Action Current Value: 0.0%~100.0% |
Energy consuming braking | Below 22KW drive built-in energy consuming braking unit, external braking resistor is optional. |
Jog running | Jog frequency range:0.1Hz~50.00Hz, JOG Acc./Dec. time: 0.0~6500.0s |
Build-in Double PID | Easily constitute a close loop control system |
Short time continuous working when power failure |
when the instantaneous power failure occurs, the load side regenerative energy compensate the voltage drop and the inverter keep running for a short time. |
Multi-stage speed running | Max 16 multi-stage speed running via build-in PLC or control terminals |
Textile swing frequency | Swing frequency available with preset and central frequency adjustable |
Auto voltage regulation | Keep a stable voltage automatically when the grid voltage transients |
Auto energy saving running | Saving energy by auto optimizing V/F curve according to the load |
Auto current limiting | Auto current limiting to prevent frequent over current fault trip |
Multi pumps control | With water supply kit, it can implement multi pumps constant pressure water supply |
Communication | Support: Modbus |
Running command channel | Keypad , Control terminal , Serial port , Above 3 channels are switchable |
Frequency setting channel | Keypad potentiometer setting: ,control panel keys setting; Function code setting: Serial port setting; Terminal up/down setting: Input Analog voltage setting: Input Analog current setting: Input pulse setting; Combination ways setting;Above ways are switchable. |
Switch input channel | FWD/REV command: 8channels programmable switch inputs, 52kinds of function can be set separately |
Analog input channel | 4~20mA: 0-10V: 2 optional analog inputs |
Analog output channel | 4~20mA or 0~10V optional, setting frequency and output frequency ,etc feature output |
Switch/pulse output channel | Programmable open collector output: relay output :0~20KHz pulse output: |
LEDdigital display | Display setting frequency, output voltage, output current, etc. |
External meter display | Display output frequency, output current, output voltage, etc. |
Key lock | All the keys can be locked |
Parameter copy | Function code parameters can be copied between inverters when use remote control panel. |
Protection function | Overcurrentprotection:overvoltageprotection:undervoltageprotection:overheating protection: overload protection, etc. Input phase loss protection ( model>2.2kw) |
Optional parts | Braking unit: remote control panel: cable: panel mounting feet, etc. |
Environment | Indoors, avoid from direct sunlight, dust, corrosive gas, oil mist, steam, water dropper salt, etc |
Altitude | Lower than 1000m (derating is necessary above 1000m) |
Ambient temperature | -10ºC~+40ºC |
Humidity | <95%RH, no condensation |
Vibration | Lower than 5.9m/s (0.6g) |
Storage temperature | -20ºC~+60ºC |
Protection level | IP20(In the selection of state display unit or the keyboard state) |
Cooling | Forced air cooling |
Installation | Wall mounted; Floor mounted |