Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer

Product Details
Customization: Available
Cooling Method: Fan Cooling, Heatsink Cooling, Natural Cooling, Oil Immersion Cooling, Water Cooling
Input Voltage: 380V
Manufacturer/Factory & Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
71
Year of Establishment
2009-06-12
  • Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
  • Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
  • Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
  • Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
  • Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
  • Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
Find Similar Products
  • Overview
  • Product Description
  • Product characteristics
  • Product features
  • Wiring diagram
  • Packaging & Shipping
  • Company Profile
  • Exhibition records
  • FAQ
Overview

Basic Info.

Model NO.
YP6000
Output Frequency
50Hz, 60Hz
Output Voltage
12V
After-sales Service
18 Months
Color
Gray
Warranty
18 Months
OEM
Suppored
Certificate
CE, ISO9001
Transport Package
Cartons and Wooden Boxes
Specification
375*255*280
Trademark
Yuanshin
Origin
China
HS Code
8537109090
Production Capacity
5000picecs/Month

Product Description

YP6000-D series built-in bypass soft starter
Product Description

The YP6000 series D-type digital AC motor soft starter is a new type of motor starting equipment designed and produced using power electronicstechnology, microprocessor technology, and modern control theory.
This product can effectively limit the starting current of asynchronous motors duringstarting, and can be widely used in loads such as fans, water pumps, conveyors, and compressors.
It is an ideal replacement for traditional star/deltaconversion, self coupling voltage reduction, magnetic control voltage reduction and other voltage reduction starting equipment.
Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer

Product characteristics

The YP6000 series D-type soft starter adopts high-performance microprocessor technology, which has higher performance and a wider range of voltageadaptation;
Four starting modes can be selected to maximize the optimal starting effect of the motor and achieve soft parking;
Chinese (Chinese display) display mode, easy to operate. The 7-color backlight LCD display can reflect the different working states of the soft starter, fullyreflecting the humanized design concept;
Multiple protection and monitoring functions, with thermal overload protection available at 6 levels according to load requirements. And can inquireabout the last three fault records and provide a basis for fault analysis;
It can provide 4-20mA analog output, RS232 (or RS485) communication interface (using MODB USRTU communication protocol), and can enterparameter setting, operation, and monitoring through the upper computer to achieve high intelligence control;
Actual power setting: When the power of the soft starter is greater than the actual load power, the rated current of the soft starter can be set according tothe actual load to match the actual power of the soft starter with the load, to ensure the accuracy of various parameters such as starting, operation, andprotection;
Programmable output relay: It can facilitate interlocking control with other devices.

 

Product features
Project Standard specification
Conforming to standard Conforming to national standards: (GB14048.6 98)
Three phase power supply voltage(VAC) AC380V(-10% +15%)
Frequency 0~50Hz
Applicable motor General squirrel cage asynchronous motor
Starting frequency Standard products suggest starting and stopping no more than 30 times per hour
Protection grade IP20
Environmental
temperature/working temperature
Between 25 ºC~+40 ºC
Storage temperature 20ºC±5ºC
Ambient humidity Relative humidity not exceeding 95%
Maximum working height If the altitude exceeds 2000 meters, the capacity will be reduced
accordingly
Cooling method Natural air cooling
Installation method Wall Mount
Wiring diagram

Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer

Packaging & Shipping
Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
Company Profile
Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer
Exhibition records

Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer

FAQ

Soft Starter Built in Bypass Soft Start 380V 22kw 3 Phase Manufacturer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier