Water Pump VFD 1.5kw Variable Frequency Inverter

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Manufacturer/Factory & Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
71
Year of Establishment
2009-06-12
  • Water Pump VFD 1.5kw Variable Frequency Inverter
  • Water Pump VFD 1.5kw Variable Frequency Inverter
  • Water Pump VFD 1.5kw Variable Frequency Inverter
  • Water Pump VFD 1.5kw Variable Frequency Inverter
  • Water Pump VFD 1.5kw Variable Frequency Inverter
Find Similar Products

Basic Info.

Model NO.
YX9000
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type
Brand
Yuanxin
Colour
Grey
Warranty
18 Months
OEM
Supported
Rated Voltage
0~380V / 415V / 440V/460V
Frequency Range
0Hz~3000Hz
Start Frequency
0.40Hz to 20.00Hz
Communication
Modbus
Transport Package
Carton/ Wood Box
Specification
plastic or metal
Trademark
Yuanshin
Origin
China
HS Code
8504409990
Production Capacity
5000 PCS / Month

Product Description

Water Pump VFD 1.5kw Variable Frequency Inverter



Water Pump VFD 1.5kw Variable Frequency Inverter

Technical Fertures
1.Standard 485 communication port, supporting PG card expansion;
2. Support backend software uploading and downloading, as well as monitoring driver parameters;
3. With various protections and rich fault handling methods, protection measures can be selected based on the fault level;
4. Equipped with the function of stacking primary and secondary frequency sources;
5. Built in PID, 16 speed, swing frequency and other functions.


Technology date 
Items Specifications
Input Rated Voltage Three phase 380V / 415V / 440V/460V; 50Hz/60Hz
Range Voltage: ±20% voltage unbalance rate:<3%; frequency: ±5%
Output Rated voltage 0~380V / 415V / 440V/460V
Frequency range 0Hz~3000Hz
Frequency resolution 0.01Hz
Overload ability 150% rated current for1minute, 180% rated current for3 seconds

Control function





Control
function
Torque control accuracy ±5%(FVC)
Control mode V/F, Sensorless vector control (SVC), Speed Sensor vector control (FVC)
Frequency accuracy Digital setting:  The highest frequency×± 0.01% Analog setting: The highest frequency ×±0.2%
Frequency resolution Digital setting: 0.01Hz; Analog setting: The highest frequency× 0.1%
Start frequency 0.40Hz~20.00Hz
Torque boost Auto torque boost, manual torque boost 0.1%~30.0%
V/F curve Five ways: constant torque V/F curve, 1 kind of user defined
V/F curve ,3 kinds of down torque curve (2.0/1.7/1.2times the power)
Acc./Dec. curve Two ways: linear Acc./Dec., S-curve Acc./Dec.;7 kinds of Acc./Dec. time, Time unit(minute/second) optional, max. time: 6000 minutes.
DC braking DC Braking Frequency: 000Hz~ Max Frequency      Braking Time: 0.0s~36.0s    
Braking Action Current Value: 0.0%~100.0%
Energy consuming  braking Below 22KW drive built-in energy consuming braking unit, 30-37KW built-in braking unit optional, external braking resistor is optional.
Jog running Jog frequency range:0.1Hz~50.00Hz, JOG Acc./Dec. time: 0.1~60.0s
Build-in Double PID Easily constitute a close loop control system
Multi-stage speed  running Max 16 multi-stage speed running via build-in PLC or control terminals
Textile swing frequency Swing frequency available with preset and central frequency adjustable
Auto voltage regulation Keep a stable voltage automatically when the grid voltage transients
Auto energy saving running Saving energy by auto optimizing V/F curve according to the load
Auto current limiting Auto current limiting to prevent frequent over current fault trip
Multi pumps control With water supply card, the function can implement multi pumps constant pressure water supply
Communication 4 field bus: Modbus, Profibus, CANlink, CANopen






Running
function
Running command channel Control panel:  control terminal :serial port :3 channels switchable
Frequency setting channel Control panel potentiometer setting:  up,down control panel keys setting; Function code setting: Serial port setting; Terminal up/down setting: Input Analog voltage setting: Input Analog current setting: Input pulse setting; Combination ways setting;
Above ways are switchable.
Input channel 8 digital input terminals, 1 of which supports up to 100KHZ high speed pulse input
2 analog input terminals, 1 support 0~10V voltage input
1 support 0~10V voltage input or 0~20mA current input
Output channel 1 high-speed pulse output terminal (optional open collector type), supporting square wave signal output of 0~100Khz
1 digital output terminal
2 relay output terminals (≥5.5kw), one relay below 5.5kw
2 analog output terminals, support 0~20mA current output or 0~10V voltage output (≥5.5kw 2 terminals) <5.5kw 1 terminal
Control panel LED digital display Display setting frequency, output voltage, output current, etc.
External meter display Display output frequency, output current, output voltage, etc.
Key lock All the keys can be locked
Parameter copy Function code parameters can be copied between          inverters when use remote control panel
Protection function Over current tprotection: overvoltageprotection:undervoltageprotection:overheating  protection: overload protection, etc.
Input phase loss protection ( model>2.2kw)
Optional parts Braking unit: remote control panel: cable: panel mounting feet, etc.
Environment Environment Indoors, free from direct sunlight, dust, corrosive gas, oil mist, steam, water dropper salt, etc
Altitude Lower than 1000m (derating is necessary above 1000m)
Ambient temperature -10ºC~+40ºC
Humidity <90%RH, no condensation
Vibration Lower than 5.9m/s  (0.6g)
Storage temperature -20ºC~+60ºC
Structure Protection level IP20(In the selection of state display unit or the keyboard state)
Cooling Forced air cooling
 Installation Wall mounted; Floor mounted

Product appearance
Water Pump VFD 1.5kw Variable Frequency Inverter

Wiring
Water Pump VFD 1.5kw Variable Frequency Inverter

Application

Water Pump VFD 1.5kw Variable Frequency Inverter
Factory
Water Pump VFD 1.5kw Variable Frequency Inverter
Exhibition
Water Pump VFD 1.5kw Variable Frequency Inverter
Certificate
Water Pump VFD 1.5kw Variable Frequency Inverter
Package and Delivery
Water Pump VFD 1.5kw Variable Frequency Inverter
FAQ: 
1. Can I get some samples? 
Yes, Sample order is available for quality check and market test. But you have to pay for it. 
2. What's delivery time? 
It usually takes about 3-5 working days for small order and 10-15 days for big order. 
3. What's your payment terms? 
We usually accept all kinds of payment terms. Such as T/T, L/C, Western Union. Cash. 
4. What's your warranty terms? 
We offer 18 months warranty time. 
5. Do you have the products in stock? 
Depends on your request, We have standard models in stock. Some special products and big order will be newly produced according to your order. 
6. Can I mix different power in one container. 
Yes, Different models can be mixed up in one container, even one order. 
7. How does your factory do the quality control? 
Quality is priority, we always attach the importance to quality control from the beginning to the end of the production. Every product will be fully assembled and carefully tested before packing and shipping. 
8. Can you sell spare parts? 
If you are using our products. We can sell spare parts to you. But we couldn't sell the half-finished products. 
9. I would like to know if you have a partner for export? 
Yes. We have the right to export and can sell electrical product all over the world...
10. Can you make the inverter and soft starter control boards (switchgear)? 
Yes. We have a lot of experience to design frequency inverter and soft starter cabinet according to your request, and our factory can do soft starter by ourselves. 
11. Can the inverter connect with computer? 
Yes. All inverters have built-in RS485 port. And support Modbus communication protocol. 
12. How can I trust you? 
Our company has been audited and approved ISO9001, CE. CCC. Assessment report will could be sent to you by e-mail. And we will take all the responsibility once problem during warranty time. 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now