Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items | Specifications | |
Input | Rated Voltage | Three phase 380V / 415V / 440V/460V; 50Hz/60Hz |
Range | Voltage: ±20% voltage unbalance rate:<3%; frequency: ±5% | |
Output | Rated voltage | 0~380V / 415V / 440V/460V |
Frequency range | 0Hz~3000Hz | |
Frequency resolution | 0.01Hz | |
Overload ability | 150% rated current for1minute, 180% rated current for3 seconds | |
Control function Control function |
Torque control accuracy | ±5%(FVC) |
Control mode | V/F, Sensorless vector control (SVC), Speed Sensor vector control (FVC) | |
Frequency accuracy | Digital setting: The highest frequency×± 0.01% Analog setting: The highest frequency ×±0.2% | |
Frequency resolution | Digital setting: 0.01Hz; Analog setting: The highest frequency× 0.1% | |
Start frequency | 0.40Hz~20.00Hz | |
Torque boost | Auto torque boost, manual torque boost 0.1%~30.0% | |
V/F curve | Five ways: constant torque V/F curve, 1 kind of user defined V/F curve ,3 kinds of down torque curve (2.0/1.7/1.2times the power) |
|
Acc./Dec. curve | Two ways: linear Acc./Dec., S-curve Acc./Dec.;7 kinds of Acc./Dec. time, Time unit(minute/second) optional, max. time: 6000 minutes. | |
DC braking | DC Braking Frequency: 000Hz~ Max Frequency Braking Time: 0.0s~36.0s Braking Action Current Value: 0.0%~100.0% |
|
Energy consuming braking | Below 22KW drive built-in energy consuming braking unit, 30-37KW built-in braking unit optional, external braking resistor is optional. | |
Jog running | Jog frequency range:0.1Hz~50.00Hz, JOG Acc./Dec. time: 0.1~60.0s | |
Build-in Double PID | Easily constitute a close loop control system | |
Multi-stage speed running | Max 16 multi-stage speed running via build-in PLC or control terminals | |
Textile swing frequency | Swing frequency available with preset and central frequency adjustable | |
Auto voltage regulation | Keep a stable voltage automatically when the grid voltage transients | |
Auto energy saving running | Saving energy by auto optimizing V/F curve according to the load | |
Auto current limiting | Auto current limiting to prevent frequent over current fault trip | |
Multi pumps control | With water supply card, the function can implement multi pumps constant pressure water supply | |
Communication | 4 field bus: Modbus, Profibus, CANlink, CANopen | |
Running function |
Running command channel | Control panel: control terminal :serial port :3 channels switchable |
Frequency setting channel | Control panel potentiometer setting: ,control panel keys setting; Function code setting: Serial port setting; Terminal up/down setting: Input Analog voltage setting: Input Analog current setting: Input pulse setting; Combination ways setting; Above ways are switchable. |
|
Input channel | 8 digital input terminals, 1 of which supports up to 100KHZ high speed pulse input 2 analog input terminals, 1 support 0~10V voltage input 1 support 0~10V voltage input or 0~20mA current input |
|
Output channel | 1 high-speed pulse output terminal (optional open collector type), supporting square wave signal output of 0~100Khz 1 digital output terminal 2 relay output terminals (≥5.5kw), one relay below 5.5kw 2 analog output terminals, support 0~20mA current output or 0~10V voltage output (≥5.5kw 2 terminals) <5.5kw 1 terminal |
|
Control panel | LED digital display | Display setting frequency, output voltage, output current, etc. |
External meter display | Display output frequency, output current, output voltage, etc. | |
Key lock | All the keys can be locked | |
Parameter copy | Function code parameters can be copied between inverters when use remote control panel | |
Protection function | Over current tprotection: overvoltageprotection:undervoltageprotection:overheating protection: overload protection, etc. Input phase loss protection ( model>2.2kw) |
|
Optional parts | Braking unit: remote control panel: cable: panel mounting feet, etc. | |
Environment | Environment | Indoors, free from direct sunlight, dust, corrosive gas, oil mist, steam, water dropper salt, etc |
Altitude | Lower than 1000m (derating is necessary above 1000m) | |
Ambient temperature | -10ºC~+40ºC | |
Humidity | <90%RH, no condensation | |
Vibration | Lower than 5.9m/s (0.6g) | |
Storage temperature | -20ºC~+60ºC | |
Structure | Protection level | IP20(In the selection of state display unit or the keyboard state) |
Cooling | Forced air cooling | |
Installation | Wall mounted; Floor mounted |