37kw Integrated Air Compressor Inverter

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Still deciding? Get samples of US$ 30/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
71
Year of Establishment
2009-06-12
  • 37kw Integrated Air Compressor Inverter
  • 37kw Integrated Air Compressor Inverter
  • 37kw Integrated Air Compressor Inverter
  • 37kw Integrated Air Compressor Inverter
  • 37kw Integrated Air Compressor Inverter
  • 37kw Integrated Air Compressor Inverter
Find Similar Products
  • Overview
  • Features
  • Specs
  • Technicial FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
YX9500B
Principle of Work
Vector Control Transducer
Switch Mode
High Carrier Frequency PWM Control
Main Circuit Type
Current
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Color
Black/Grey
Type
Yx9000
Warranty
18 Months
Control Mode
Vector Control
Samples
Approval
OEM
Acceptable
Delivery Time
3-5 Wokrdays Within 200PCS
Material
Plastic/Metal
Packing
Carton Box/Plywood
Brake Unit
45kw Below Built-in Brake Unit
EMC Filter
Bui;T-in
Transport Package
Carton Box/Plywood
Specification
Plastic/Metal
Trademark
Yuanshin
Origin
China
HS Code
8504409990
Production Capacity
15000PCS Per Month

Product Description


37KW Integrated Air Compressor Inverter

YX9500B series variable frequency drive, 3 phase 380V/415V/480V, RS485 communication mode and IP 20 enclosure rating. The frequency drive inverter is specially used in air compressor application

Features
 
  1. The LED display of the vfd inverter 3 phase can display the set frequency, output voltage, output current, etc.
  2. With an IP20 shell protection level, the 3 phase variable frequency drive can be forced air-cooled to stabilize the internal temperature and protect parts from damage.
  3. The installation methods of the frequency drive inverter include wall-mounted and floor-standing. The installation method can be adjusted according to the actual situation
  4. The PLC operation, multi-speed operation, and normal operation of the variable frequency inverter can be used for external swing frequency operation
  5. Classic layout control panel, simple and easy to use, high security performance.
  6. Built-in brake units and EMC filters, external adding brake resistors, AC reactors, DC chocks ect can make sure the variable speed drive work steady.
 
Specs
Basics Model YX9500B series
Power capacity 7.5KW-37KW
Color Black in standard, other colors in optional
Control mode Vector control
I/O Features Input voltage 3 phase 380V(range:304V-456V); 3 phase 415V(range:323V-528V)
Output voltage 0-input voltage
Input frequency 50/60Hz
Output frequency 0-500Hz
Rated output current 39A
Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control Feature Communication RS485
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating  
Temperature -10ºC~ +40ºC; VFD will be derated if ambient temperature exceed 40ºC; each rise 1ºC, the derate will be 5%
Humidity 5%-95%, without condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment
-20ºC~ +60ºC; no dust, no corrosive gas, no direct sunlight
Technicial FAQ
37kw Integrated Air Compressor Inverter
How to connect the frequency inverters?


usually there is two ways for connecting the motors, before you connection, please make sure you use Star connection or Delta connection, you can see the connection diagram as left picture.
 
 
37kw Integrated Air Compressor Inverter
How to Check the IGBT failure?

 

1. Use the diode position of the multimeter, the red pen to point the three-phase output terminals (U, V, W), the black pen point "+", measure whether the three-phase bridge on the inverter part is normal or not, and the multimeter shown about 0.4V is Normal, short circuit or open circuit means damage, as shown in left picture.

37kw Integrated Air Compressor Inverter
How to check the IGBT failure?


2. Use the multimeter diode position, the red pen point "-", and the black pens point the three-phase input terminals (U, V, W). Measure whether the three-phase lower bridge of the rectifier part is normal or not. The multimeter showing about 0.4V is Normal, short circuit or open circuit shows damage, as shown in left picture.

 

Company Profile

37kw Integrated Air Compressor Inverter37kw Integrated Air Compressor Inverter

37kw Integrated Air Compressor Inverter

37kw Integrated Air Compressor Inverter37kw Integrated Air Compressor Inverter
37kw Integrated Air Compressor Inverter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier