2.2 kW Single Phase Output Frequency Inverter
This single phase output frequency drive for single phase motor can power your single-phase motor with variable speeds. Equipped with LED display and cooling fan, variable frequency drive inverters are usually applied in manufacturing, construction, power industry sewage treatment, etc.
Basics | Model | YX9000 series |
Power capacity | 2.2KW/3HP | |
Color | Black in standard, other colors in optional | |
Control mode | Vector control | |
I/O Features | Input voltage | 1 phase 220V(range:176V-264V); 3 phase 380V(range:304V-456V); 3 phase 415V(range:323V-528V); 3 phase 220V(range:176V-264V) |
Output voltage | 0-input voltage | |
Input frequency | 50/60Hz | |
Output frequency | 0-500Hz | |
Rated output current | 9.6A | |
Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
Control Feature | Communication | RS485 |
Speed regulation | 1:100 | |
Start torque | 150% of rating torque at 1 Hz | |
Speed control accuracy | ≤±0.5% of rating synchronous speed | |
Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% |
|
Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz |
|
Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
Interior PID controller | Be convenient to make closed-loop system | |
Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
Environment | Enclosure rating | |
Temperature | -10ºC~ +40ºC; VFD will be derated if ambient temperature exceed 40ºC; each rise 1ºC, the derate will be 5% | |
Humidity | 5%-95%, without condensation | |
Altitude | ≤1000m; VFD will be derated if above 1000m | |
Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
Store environment |
|
1. Use the diode position of the multimeter, the red pen to point the three-phase output terminals (U, V, W), the black pen point "+", measure whether the three-phase bridge on the inverter part is normal or not, and the multimeter shown about 0.4V is Normal, short circuit or open circuit means damage, as shown in left picture.