Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The V910 series IP54 fully enclosed frequency converter is a brand new product developed by Yuanxin Electric for complex usage environments. It can be used efficiently for a long time in environments with water flow, metal dust, humidity, and corrosive components, solving the problems of short service life and high equipment cost of frequency converters in harsh environments for users. It improves production efficiency while reducing production costs.
Items | Specifications |
Rated Input Voltage | 220V / 380V / 415V / 440V; 50Hz/60Hz |
Tolerance | Voltage: ±20% voltage unbalance rate:<3%; frequency: ±5% |
Rated Output voltage | 220V /380V / 415V / 440V |
Frequency range | 0Hz~5000Hz |
Frequency resolution | 0.01Hz |
Overload capability | 150% rated current for 1 minute, 180% rated current for 3 seconds |
Torque control accuracy | ±5%(FVC) |
Control mode | V/F, sensorless vector control (SVC), Speed Sensor vector control(FVC) |
Frequency Accuracy | Digital setting: The highest frequency×± 0.01% Analog setting: The highest frequency ×±0.2% |
Frequency resolution | Digital setting: 0.01Hz; Analog setting: The highest frequency× 0.1% |
Start frequency | 0.40Hz~20.00Hz |
Torque boost | Auto torque boost, manual torque boost 0.1%~30.0% |
V/F curve | Five ways: constant torque V/F curve, 1 kind of user defined V/F curve ,3 kinds of down torque curve(2.0/1.7/1.2times the power) |
Acc./Dec. curve | Two ways: linear Acc./Dec.,S-curveAcc./Dec.;7 kinds of Acc./Dec. time, Time unit(minute/second) optional, max. time: 6000 minutes. |
DC braking | DC Braking Frequency: 000Hz~ Max Frequency Braking Time: 0.0s~36.0s Braking Action Current Value: 0.0%~100.0% |
Energy consuming braking | Below 22KW drive built-in energy consuming braking unit, external braking resistor is optional. |
Jog running | Jog frequency range:0.1Hz~50.00Hz, JOG Acc./Dec. time: 0.0~6500.0s |
Build-in Double PID | Easily constitute a close loop control system |
Short time continuous working when power failure |
when the instantaneous power failure occurs, the load side regenerative energy compensate the voltage drop and the inverter keep running for a short time. |
Multi-stage speed running | Max 16 multi-stage speed running via build-in PLC or control terminals |
Textile swing frequency | Swing frequency available with preset and central frequency adjustable |
Auto voltage regulation | Keep a stable voltage automatically when the grid voltage transients |
Auto energy saving running | Saving energy by auto optimizing V/F curve according to the load |
Auto current limiting | Auto current limiting to prevent frequent over current fault trip |
Multi pumps control | With water supply kit, it can implement multi pumps constant pressure water supply |
Communication | Support: Modbus |
Running command channel | Keypad , Control terminal , Serial port , Above 3 channels are switchable |
Frequency setting channel | Keypad potentiometer setting: ,control panel keys setting; Function code setting: Serial port setting; Terminal up/down setting: Input Analog voltage setting: Input Analog current setting: Input pulse setting; Combination ways setting;Above ways are switchable. |
Switch input channel | FWD/REV command: 8channels programmable switch inputs, 52kinds of function can be set separately |
Analog input channel | 4~20mA: 0-10V: 2 optional analog inputs |
Analog output channel | 4~20mA or 0~10V optional, setting frequency and output frequency ,etc feature output |
Switch/pulse output channel | Programmable open collector output: relay output :0~20KHz pulse output: |
LEDdigital display | Display setting frequency, output voltage, output current, etc. |
External meter display | Display output frequency, output current, output voltage, etc. |
Key lock | All the keys can be locked |
Parameter copy | Function code parameters can be copied between inverters when use remote control panel. |
Protection function | Overcurrentprotection:overvoltageprotection:undervoltageprotection:overheating protection: overload protection, etc. Input phase loss protection ( model>2.2kw) |
Optional parts | Braking unit: remote control panel: cable: panel mounting feet, etc. |
Environment | Indoors, avoid from direct sunlight, dust, corrosive gas, oil mist, steam, water dropper salt, etc |
Altitude | Lower than 1000m (derating is necessary above 1000m) |
Ambient temperature | -10ºC~+40ºC |
Humidity | <95%RH, no condensation |
Vibration | Lower than 5.9m/s (0.6g) |
Storage temperature | -20ºC~+60ºC |
Protection level | IP20(In the selection of state display unit or the keyboard state) |
Cooling | Forced air cooling |
Installation | Wall mounted; Floor mounted |